| Sign In | Join Free | My insurersguide.com | 
              
  | 
      
Place of Origin : Anhui, China
Brand Name : WNK
Model Number : WLD
Packaging Details : One set in per carton, standard packing
Supply Ability : 1000 Piece/Pieces per Month
Price : $480.00/Pieces >=1 Pieces
Type : Variable Area Water Flowmeters
Maximum flow rate : 15m/s
Fluid conductivity : ≥5μs/cm
Ambient temperature : -25~60℃,-10~60℃
Liner material : PTFE/PVF/F46/Neoprene/PUR
Fluid maximum temperature : 100℃,150℃
Signal electrode form : DN15-DN2600,DN300-DN1600
Electrode material : SS316L,Hastelloy C,Hastelloy B,Titanium,Tantalum,Platinum Iridium
Connecting flange material : Carbon Steel
Grounding flange material : SST 1Cr18Ni9Ti
Protection : IP65/68
Port : Shanghai
|  			 WLD electromagnetic flowmeter is manufactured with the latest technology with the following defects:  			 |  			 			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 - Measurements are not affected by changes in fluid density, viscosity, temperature, pressure and conductivity;  			 |  			 			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 - Unobstructed flow components in the measuring tube, no pressure loss, low requirements for straight pipe sections;  			 |  			 			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 - Series nominal diameter DN3-DN3000. There are many options for sensor liner and electrode materials;  			 |  			 			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 - The converter adopts novel excitation mode, low power consumption, stable zero point and high precision. The flow range can be1500:1  			 |  			 			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 - The converter can be integrated or separated from the sensor;  			 |  			 			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 - The converter adopts 16-bit high-performance microprocessor, 2X16LCD display, convenient parameter setting and reliable programming;  			 |  			 			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 - Explosion-proof instruments can be used in corresponding explosion-proof places;  			 |  			 			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 - The converter uses surface mount technology (SMT) with self-test and self-diagnosis functions;  			 |  			 			 |  			 			 |  			 			 |  			 			 |  		||||
|  			 Maximum Flow Rate  			 |  			 			 |  			 			 15m/s  			 |  			 			 |  			 			 |  		|||
|  			 Nominal Pressure  			 |  			 			 |  			 			 DN15~DN150  			 |  			 			 |  			 			 4.0Mpa  			 |  		|||
|  			 |  			 			 |  			 			 DN15~DN600  			 |  			 			 |  			 			 1.6Mpa  			 |  		|||
|  			 |  			 			 |  			 			 DN200~DN1000  			 |  			 			 |  			 			 1.0Mpa  			 |  		|||
|  			 |  			 			 |  			 			 DN700~DN3000  			 |  			 			 |  			 			 0.6Mpa  			 |  		|||
|  			 Ambient Temperature  			 |  			 			 |  			 			 Sensor  			 |  			 			 |  			 			 -25~60℃  			 |  		|||
|  			 |  			 			 |  			 			 Coverter  			 |  			 			 |  			 			 -10~60℃  			 |  		|||
|  			 Liner material and fluid maximum temperature  			 |  			 			 |  			 			 Liner material  			 |  			 			 Separate type  			 |  			 			 Integrated type  			 |  		|||
|  			 |  			 			 |  			 			 PTFE  			 |  			 			 100℃;150℃  			 |  			 			 70℃  			 |  		|||
|  			 |  			 			 |  			 			 PVF  			 |  			 			 100℃;150℃  			 |  			 			 70℃  			 |  		|||
|  			 |  			 			 |  			 			 FEP  			 |  			 			 100℃;150℃  			 |  			 			 70℃  			 |  		|||
|  			 |  			 			 |  			 			 Neoprene  			 |  			 			 80℃;120℃  			 |  			 			 70℃  			 |  		|||
|  			 |  			 			 |  			 			 PUR  			 |  			 			 80℃  			 |  			 			 70℃  			 |  		|||
|  			 Signal electrode form  			 |  			 			 |  			 			 Fixed (DN15~DN2600) Scraper(DN300-DN1600)  			 |  			 			 |  			 			 |  		|||
|  			 Electrode material  			 |  			 			 |  			 			 SS316L,Hastelloy C,Hastelloy B,Titanium,Tantalum,Platinum Iridium  			 |  			 			 |  			 			 |  		|||
|  			 Connecting flange Material  			 |  			 			 |  			 			 Carbon Steel  			 |  			 			 |  			 			 |  		|||
|  			 Grounding flange material  			 |  			 			 |  			 			 SST 1Cr18Ni9Ti  			 |  			 			 |  			 			 |  		|||
|  			 Imported prodective flange material  			 |  			 			 |  			 			 DN15~DN600  			 |  			 			 |  			 			 SST 1Cr18Ni9Ti  			 |  		|||
|  			 |  			 			 |  			 			 DN700-DN3000  			 |  			 			 |  			 			 Carbon Steel  			 |  		|||
|  			 Protection  			 |  			 			 |  			 			 DN15-DN150 Separate rubber and polyurethane liner sensors  			 |  			 			 |  			 			 IP65.68(Special customize)  			 |  		|||
|  			 |  			 			 |  			 			 DN200-DN2600 Separate rubber and polyurethane liner sensors  			 |  			 			 |  			 			 IP68 under water 10 meters  			 |  		|||
|  			 |  			 			 |  			 			 Other sensor converter  			 |  			 			 |  			 			 IP65  			 |  		|||
|  			 Spacing(separate type )  			 |  			 			 |  			 			 The Spacing Less than or equal to 100 meters or need Special customize  			 |  			 			 |  			 			 |  		|||














| 
                                             | 
                
                        Electromagnetic Digital Flow Meter High Precision For Liquid Images |